6kW SOLAR SYSTEM with 6kW Hybrid Inverter + 5kWh Battery + 6kWp Solar Panels for SANDWICH PANEL ROOF WITH ADDITIONAL TILT MOUNTING STRUCTURE
-
Code:Deye-6kW1P+5kWh+6kWp-dopulnitelen-naklon
-
Weight:750.000 Kgs
Quick Buy
6kW Solar System with Deye Hybrid Inverter, 5.12kWh LiFePO4 Battery and 6.05kWp Solar Panels for Sandwich Panel Roof with Additional Tilt
The 6kW Solar System for Sandwich Panel Roof with Additional Tilt is a complete photovoltaic equipment package designed for solar electricity generation, battery energy storage and intelligent energy management.
The system combines a 6kW Deye single-phase hybrid inverter, a 5.12kWh LVFU LiFePO4 battery, 10 JA Solar 605W N-Type bifacial solar panels and a specialized KT-AR2-SC mounting structure for a north-facing roof slope with additional or reverse tilt.
The photovoltaic array provides 6.05kWp (6050Wp) total rated solar capacity, while the inverter delivers 6kW rated AC power. The included 5.12kWh battery stores part of the generated electricity for later use, subject to battery operating limits and system settings.
This configuration is intended for suitable sandwich panel roofs where an additional mounting angle is required. The included AR2 mounting structure for a north-facing roof slope allows a project-specific panel tilt arrangement rather than simply following the original roof surface.
The system can be suitable for houses, holiday properties, workshops, warehouses, agricultural buildings and small commercial premises, provided that the roof structure and electrical installation meet the required design criteria.
Key Features and Benefits
- 6kW Deye hybrid inverter – SUN-6K-SG06LP1-EU single-phase On-Grid/Off-Grid model.
- 5.12kWh LiFePO4 battery – LVFU LFR51100, 51.2V, 100Ah.
- 6.05kWp installed solar capacity – 10 JA Solar bifacial N-Type modules rated at 605W each.
- Additional solar panel tilt – using 10 KT-AR2-SC mounting structure sets.
- North-facing roof slope configuration – for projects requiring a modified panel inclination.
- Bifacial photovoltaic technology – potential additional rear-side energy generation.
- Low-voltage battery energy storage – for improved solar energy management.
- Battery connection cables included – red and black, 1500mm, 25mm².
- Solar DC cables included – black and red KBE H1Z2Z2-K, 1×6mm², 1500V DC.
- DC and AC protection boards included – for the relevant system circuits.
- Grounding components included – for protective earthing according to the electrical design.
- Delivery and transportation included as part of the listed package.
Main System Specifications
| Parameter | Specification |
|---|---|
| System Type | Single-Phase Hybrid Photovoltaic System with Battery Storage |
| Rated Inverter Power | 6kW |
| Inverter Brand | Deye |
| Inverter Model | SUN-6K-SG06LP1-EU |
| Inverter Operating Modes | On-Grid / Off-Grid |
| Battery Technology | Low-Voltage LiFePO4 |
| Battery Brand and Model | LVFU LFR51100 |
| Nominal Battery Energy | 5.12kWh |
| Nominal Battery Voltage | 51.2V |
| Battery Capacity | 100Ah |
| Stated Battery Cycle Life | 6000 Cycles |
| Solar Panel Manufacturer | JA Solar |
| Solar Panel Model | JAM72D40-605/MB-SF |
| Rated Power per Panel | 605Wp |
| Number of Panels | 10 |
| Total Rated PV Capacity | 6050Wp / 6.05kWp |
| Solar Panel Technology | N-Type Bifacial |
| Solar Panel Frame | Grey, 30mm |
| Panel Dimensions Listed in Proforma | 2278 × 1134 × 30mm |
| Mounting Application | Sandwich Panel Roof with Additional/Reverse Tilt |
| Mounting Structure | KT-AR2-SC, AR2 for North-Facing Roof Slope |
| Number of Mounting Structure Sets | 10 |
| DC Protection Board | DC2-600V16AIP20, Two Strings, 600V, 16A, IP20 |
| AC Protection Board | AC-1Phase-3-16KW, Single-Phase, with ATS and Protection |
| Delivery Included | Yes, According to Package List |
| Installation Included | No |
Complete System Package – Bill of Materials
The package includes the following equipment, components and services:
| No. | Product Code | Description | Quantity |
|---|---|---|---|
| 1 | SUN-6K-SG06LP1-EU | Deye 6kW Single-Phase Hybrid Inverter, On-Grid/Off-Grid | 1 pc |
| 2 | LFR51100 | LVFU 5.12kWh LiFePO4 Battery, 51.2V, 100Ah, 6000 Cycles | 1 pc |
| 3 | 25CAB0810 | Red/Black Battery-to-Inverter Cable Set, 1500mm, 25mm², 8–10mm Terminal Holes | 1 set |
| 4 | JAM72D40-605/MB-SF | JA Solar 605W N-Type Bifacial Solar Panel, Grey Frame | 10 pcs |
| 5 | KT-AR2-SC | AR2 Mounting Structure for North-Facing Roof Slope with Additional Tilt | 10 sets |
| 6 | 730600015064QUSW | Black KBE H1Z2Z2-K Solar DC Cable, 1×6mm², 1500V DC | 50 Invoice Units |
| 7 | 730600015064QURT | Red KBE H1Z2Z2-K Solar DC Cable, 1×6mm², 1500V DC | 50 Invoice Units |
| 8 | O9455 | MC4 1:1 Solar PV Connector, 1000V, 30A | 4 pcs |
| 9 | 240220033 | ШВПСВ Electrical Cable, 5×6mm² | 10 Invoice Units |
| 10 | 400020022 | Hot-Dip Galvanized Grounding Rod, Ø20mm, 1.5m Length | 2 pcs |
| 11 | 400030032 | Cross Grounding Clamp for Ø20mm Rod and 40/4 Strip | 1 pc |
| 12 | 240100059 | Yellow/Green PV A2 Grounding Conductor, 10mm² | 25 Invoice Units |
| 13 | DC2-600V16AIP20 | Two-String DC Protection Board, 600V, 16A, IP20, with Surge/Lightning Protection Components | 1 pc |
| 14 | AC-1Phase-3-16KW | Single-Phase AC Board for 3–16kW Hybrid Inverters, 18 Rows as Listed, IP20, with Surge Protection, ATS and Fuse | 1 pc |
| 15 | 20010023 | NOARK Ex9BN 1P C10 Miniature Circuit Breaker, 6kA | 1 pc |
| 16 | 800000043 | Delivery / Transportation | 1 Service |
| 17 | SKARA230115 | Transportation Pallet, 230 × 115cm | 1 pc |
| 18 | SKU1010101010 | Equipment Installation – Not Included in the Package Price | Not Included |
Note: Cable quantities are shown as invoice units because the source proforma uses a generic "pieces" unit. Actual cable lengths required for installation must be confirmed for the specific site.
Deye SUN-6K-SG06LP1-EU – 6kW Single-Phase Hybrid Inverter
The system is built around the Deye SUN-6K-SG06LP1-EU, a 6kW single-phase hybrid inverter supporting On-Grid and Off-Grid configurations.
The hybrid architecture enables coordinated energy management between the photovoltaic array, compatible battery storage and the utility grid.
This inverter is suitable for systems designed to increase on-site solar electricity consumption and make stored energy available when required.
Specific backup operating modes, battery communication settings and electrical connections must be configured according to the manufacturer's documentation and the system design.
LVFU LFR51100 – 5.12kWh LiFePO4 Solar Battery
The package includes one LVFU LFR51100 low-voltage lithium iron phosphate battery with 5.12kWh nominal energy capacity.
Key specifications:
- Battery chemistry: LiFePO4.
- Nominal energy: 5.12kWh.
- Nominal voltage: 51.2V.
- Rated capacity: 100Ah.
- Stated cycle life: 6000 cycles.
- Quantity: One battery.
The battery stores part of the solar electricity generated during the day for use at other times, depending on system configuration and energy demand.
Important: The stated 5.12kWh is nominal energy capacity. Actual usable energy depends on the permitted depth of discharge, BMS settings, operating conditions and conversion losses.
10 JA Solar 605W N-Type Bifacial Solar Panels
The photovoltaic array includes 10 JA Solar JAM72D40-605/MB-SF modules, each rated at 605Wp.
Total installed photovoltaic capacity:
10 × 605Wp = 6050Wp = 6.05kWp.
These panels feature N-Type cell technology and a bifacial design, allowing electricity generation from sunlight reaching both the front and rear sides.
According to the source proforma, the panels have a grey frame and dimensions of 2278 × 1134 × 30mm.
The potential rear-side energy gain depends on the roof surface, mounting geometry, clearance beneath the panels and actual lighting conditions.
Exact mechanical and electrical specifications of the supplied module batch should be verified before installation.
KT-AR2-SC – Additional Tilt Mounting Structure for Sandwich Panel Roofs
A key feature of this system is the specialized KT-AR2-SC mounting structure, described in the source proforma as an AR2 structure for a north-facing roof slope.
The package includes 10 mounting structure sets for the photovoltaic modules.
This type of arrangement is intended for projects where the existing roof slope does not provide the preferred panel inclination or orientation.
The additional tilt structure can enable a different module angle relative to the original roof plane, potentially improving solar exposure when properly designed.
Important: Sandwich panel roof installations require verification of roof load capacity, fastening points, wind uplift, snow loads and waterproofing. Elevated solar structures can experience significant wind forces, so the final design must be approved for the specific roof and location.
Why Choose an Additional Tilt Solar Mounting Structure?
When a roof has an unfavorable orientation, mounting solar panels directly parallel to the roof surface may not provide the desired solar exposure.
An additional tilt mounting structure allows the photovoltaic array to be positioned at a different angle.
Potential benefits include:
- Greater flexibility in panel orientation.
- Potential improvement in annual solar electricity generation under suitable conditions.
- Better utilization of certain north-facing roof surfaces.
- Project-specific optimization of the photovoltaic array layout.
The exact tilt angle must be determined through system design. No fixed mounting angle is specified in the supplied proforma.
Solar DC Cables, Connectors and Electrical Components
The system includes black and red KBE H1Z2Z2-K solar cables with a conductor cross-section of 1×6mm² and a specified rating of 1500V DC.
It also includes four MC4-type PV connectors rated at 1000V and 30A.
The battery connection cable set consists of red and black conductors with a specified length of 1500mm and cross-section of 25mm².
An additional ШВПСВ 5×6mm² electrical cable is included for the relevant AC wiring requirements.
Final cable routes, lengths, conductor sizing and protection must be verified by a qualified electrician.
Two-String DC Protection Board
The package includes one DC2-600V16AIP20 protection board with the following listed specifications:
- Two photovoltaic strings.
- 600V DC rated voltage.
- 16A specified current.
- IP20 enclosure rating.
- Surge/lightning protection components.
Important: An IP20 enclosure is not suitable for direct exposure to rain. The installation environment must match the protection rating.
Single-Phase AC Board with ATS and Protection
The included AC-1Phase-3-16KW is a single-phase AC board intended for compatible hybrid inverter systems in the stated 3–16kW range.
The supplier's description lists:
- 18 rows as specified in the source document.
- IP20 enclosure protection.
- Surge protection components.
- Lightning protection components.
- ATS automatic transfer functionality according to the electrical design.
- Fuse protection.
The package also includes a NOARK Ex9BN 1P C10 6kA miniature circuit breaker.
The ATS and backup load wiring must be designed in accordance with the inverter manufacturer's requirements and applicable electrical regulations.
Grounding and Electrical Safety Components
The package contains the following grounding materials:
- Two galvanized grounding rods, Ø20mm and 1.5m long.
- One cross grounding clamp for a Ø20mm rod and 40/4 strip.
- 25 invoice units of yellow/green 10mm² grounding conductor.
Protective earthing, equipotential bonding and surge protection must be installed according to the approved electrical design and applicable regulations.
On-Grid and Off-Grid Energy Management
The Deye hybrid inverter enables coordinated operation of the solar panels, battery storage and utility grid according to the selected system settings.
In grid-connected operation, the system can be configured to prioritize on-site consumption of photovoltaic electricity.
In a correctly designed backup or standalone configuration, selected electrical loads may also be supplied when the utility grid is unavailable.
Actual backup duration depends on usable battery capacity, connected loads, solar production and the operating limits of the inverter and battery.
Suitable Applications
- Residential houses with suitable sandwich panel roofs.
- Holiday homes and rural properties requiring solar generation and battery storage.
- Workshops and warehouses with structurally suitable roofs.
- Agricultural buildings with appropriate electrical and structural design.
- Small commercial premises seeking to optimize on-site electricity consumption.
- North-facing roof slopes where an additional tilt structure is part of the approved project.
Important Installation Considerations
- Verify the structural capacity of the sandwich panel roof.
- Confirm compatibility of KT-AR2-SC with the roof profile and supporting structure.
- Assess wind uplift and snow loads for the elevated array.
- Determine the appropriate panel orientation and tilt angle.
- Check shading from nearby structures and between panel rows.
- Verify photovoltaic string voltages and currents against inverter limits.
- Confirm battery-to-inverter compatibility and BMS communication.
- Review the DC and AC protection design, ATS and grounding.
- Determine whether additional cables or mounting accessories are required for the site.
Frequently Asked Questions
What is the rated power of this solar system?
The hybrid inverter is rated at 6kW. The photovoltaic array consists of 10 panels rated at 605W each, providing 6.05kWp total installed solar capacity.
What battery is included?
The package includes one LVFU LFR51100 LiFePO4 battery rated at 5.12kWh, 51.2V and 100Ah.
Which inverter is included?
The included inverter is the Deye SUN-6K-SG05LP1-EU, a 6kW single-phase On-Grid/Off-Grid hybrid model.
Which solar panels are included?
The system includes 10 JA Solar JAM72D40-605/MB-SF N-Type bifacial modules with grey frames, each rated at 605W.
What does additional tilt mean?
It means using a specialized mounting structure that allows the panels to be positioned at a different angle from the original roof plane.
Is the system suitable for a north-facing roof slope?
The package includes the KT-AR2-SC mounting structure, described as an AR2 system for a north-facing slope. Suitability must be confirmed through site assessment and structural design.
Are AC and DC protection boards included?
Yes. The package includes a two-string DC protection board and a single-phase AC board with ATS and protective components.
Is installation included?
No. Equipment installation is explicitly excluded from the package price.
Is delivery included?
Yes. Delivery and transportation are included as a separate item in the supplied package list.
Can the system supply electricity during a power outage?
The inverter supports Off-Grid operation. Actual backup capability depends on correct backup load wiring, battery operation and protective switching configuration.
Order the 6kW Solar System with Additional Tilt for Sandwich Panel Roofs from VOLTON.BG
Choose the 6kW Deye Hybrid Solar System with 5.12kWh LiFePO4 Battery, 6.05kWp JA Solar Panels and KT-AR2-SC Additional Tilt Mounting Structure for a suitable sandwich panel roof installation.
Contact VOLTON.BG for current pricing, availability, delivery information and technical assistance with selecting the correct mounting arrangement for your roof.
Phone: +359 878 307765
Email: sales@volton.bg
Website: www.volton.bg
-
Warranty:10 years